AC Resonant Test System

Our AC Resonant Test System is engineered for high voltage testing applications, particularly in power systems where large capacitive loads are present. Utilizing the principle of electrical resonance, this system achieves higher test voltages with lower power requirements, making it efficient and cost-effective.

lizhvtesttech@gmail.com

+1 323 522 4623

Key Features:

  • High Voltage Output: Capable of generating high voltages required for testing large electrical apparatuses such as GIS, cables, transformers, and switchgear.
  • Energy Efficiency: By operating in resonance, the system significantly reduces power consumption, making it more energy-efficient compared to traditional test systems.
  • Modular Design: Our system features a modular design, allowing for easy transportation, installation, and scalability to meet various testing needs.
  • Precise Control: Equipped with advanced control systems, our resonant test equipment offers precise voltage regulation and frequency adjustment, ensuring accurate test conditions.
  • Safety Mechanisms: Includes multiple safety features such as overvoltage and overcurrent protection, emergency stop, and zero start interlock to ensure operator and equipment safety.

Applications:

  • Gas Insulated Switchgear (GIS): Ensures the dielectric strength of GIS installations.
  • High Voltage Cables: Tests the insulation and dielectric strength of high voltage cables over long lengths.
  • Power Transformers: Evaluates the insulation properties and operational reliability of power transformers.
  • Switchgear and Circuit Breakers: Assesses the dielectric integrity of switchgear and circuit breakers.
  • Rotating Machines: Suitable for high voltage testing of large motors and generators.

Product Range:

  1. Portable Resonant Test Systems:
    • Ideal for field testing and on-site verification.
    • Lightweight and easy to transport.
  2. Fixed Resonant Test Systems:
    • Suitable for laboratory and manufacturing environments.
    • Designed for high voltage and high power applications.
  3. Variable Frequency Resonant Test Systems:
    • Provides flexibility in frequency adjustment to achieve resonance.
    • Suitable for various capacitive loads.

Technical Specifications:

  • 108kVA 108kV AC Resonant Test System

    • Input Voltage: 380V
    • Output Voltage: 0-108kV
    • Capacity: 108kVA
    • Application:
      • 35kV transformers, circuit breakers, insulators
      • 10kV cables (300 mm², 2000m)
      • 35kV cables (300 mm², 500m)
    • Main Configurations:
      • Variable frequency source (5kW)
      • Exciting transformer (5kVA)
      • Reactors (27kV/1A, 4 sets)
      • Capacitive divider (100kV)
  • 216kVA 216kV AC Resonant Test System

    • Input Voltage: 380V
    • Output Voltage: 0-216kV
    • Capacity: 216kVA
    • Application:
      • 110kV circuit breakers, GIS
      • 35kV cables (300 mm², 1500m)
      • 10kV cables (300 mm², 3km)
    • Main Configurations:
      • Variable frequency source (10kW)
      • Exciting transformer (10kVA)
      • Reactors (54kV/1A, 4 sets)
      • Capacitive divider (200kV)
  • 270kVA 270kV AC Resonant Test System

    • Input Voltage: 380V
    • Output Voltage: 0-270kV
    • Capacity: 270kVA
    • Application:
      • 110kV GIS, transformers
      • 35kV cables (300 mm², 2km)
    • Main Configurations:
      • Variable frequency source (15kW)
      • Exciting transformer (15kVA)
      • Reactors (54kV/1A, 4 sets)
      • Capacitive divider (300kV)
  • 400kVA 400kV AC Resonant Test System

    • Input Voltage: 380V
    • Output Voltage: 0-400kV
    • Capacity: 400kVA
    • Application:
      • 220kV GIS, transformers
      • 10kV cables (300 mm², 4km)
      • 35kV cables (300 mm², 1km)
    • Main Configurations:
      • Variable frequency source (20kW)
      • Exciting transformer (20kVA)
      • Reactor (100kV/1A, 4 sets)
      • Capacitive divider (400kV)
  • 600kVA 600kV AC Resonant Test System

    • Input Voltage: 380V
    • Output Voltage: 0-600kV
    • Capacity: 600kVA
    • Application:
      • 110kV cables (300 mm², 800m)
      • 35kV cables (300 mm², 110m)
      • 35-220kV GIS, transformers, insulators
    • Main Configurations:
      • Variable frequency source (30kW)
      • Exciting transformer (30kVA)
      • Reactor (120kV/1A, 5 sets)
      • Capacitive divider (600kV)
  • 800kVA 800kV AC Resonant Test System

    • Input Voltage: 380V
    • Output Voltage: 0-800kV
    • Capacity: 800kVA
    • Application:
      • 110kV cables (300 mm², 800m)
      • 220kV cables (300 mm², 500m)
      • 35-500kV GIS, transformers, insulators
    • Main Configurations:
      • Variable frequency source (40kW)
      • Exciting transformer (40kVA)
      • Reactor (200kV/1A, 4 sets)
      • Capacitive divider (800kV)

Why Choose Our AC Resonant Test System?

  • Efficiency and Reliability: Our systems are designed to deliver high efficiency and reliable performance, reducing operational costs and downtime.
  • Compliance with Standards: Meets international standards such as IEC, IEEE, and ANSI, ensuring standardized testing procedures and results.
  • Customization Options: We offer customizable solutions tailored to meet specific testing requirements and scenarios.
  • Expert Technical Support: Our team of experienced engineers provides comprehensive support, from system setup to ongoing maintenance and troubleshooting.