{"id":3787,"date":"2025-01-16T12:53:32","date_gmt":"2025-01-16T12:53:32","guid":{"rendered":"https:\/\/hvtesttech.com\/?p=3787"},"modified":"2025-12-02T01:30:33","modified_gmt":"2025-12-02T01:30:33","slug":"resistance-measurement-connections-for-transformers-a-detailed-guide","status":"publish","type":"post","link":"https:\/\/hvtesttech.com\/da\/resistance-measurement-connections-for-transformers-a-detailed-guide\/","title":{"rendered":"Resistance Measurement Connections for Transformers: A Detailed Guide"},"content":{"rendered":"<p><strong>Introduction<\/strong><\/p>\n\n\n\n<p>Resistance measurements are a fundamental part of transformer maintenance and diagnostics. Ensuring that the connections for these tests are made correctly not only guarantees accurate readings but also maintains safety and efficiency. In this article, we\u2019ll dive into practical steps, key considerations, and real-world advice on how to set up resistance measurement connections for transformers. As a professional electrical testing expert, I\u2019ll also share some personal insights gained from years in the field.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Understanding the Purpose of Resistance Measurements<\/strong><\/h2>\n\n\n\n<p>Resistance measurements are typically conducted on transformer windings to identify issues such as:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Poor electrical contacts.<\/li>\n\n\n\n<li>Internal damage or deterioration.<\/li>\n\n\n\n<li>Uneven distribution of current due to resistive imbalances.<\/li>\n<\/ul>\n\n\n\n<p>These tests are crucial both for new transformers (as part of commissioning tests) and for those in service (as part of periodic maintenance checks). Identifying problems early can prevent costly failures and unplanned outages.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Preparation and Safety Considerations<\/strong><\/h2>\n\n\n\n<p>Before making any connections, it\u2019s essential to:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Verify Equipment Calibration:<\/strong><br>Using calibrated instruments ensures that the measurements are reliable. This involves checking the calibration certificate and performing a quick functional test on a known standard.<\/li>\n\n\n\n<li><strong>Check the Transformer Status:<\/strong><br>Ensure the transformer is de-energized, grounded, and discharged. Confirm that all necessary work permits are in place.<br><em>Personal Anecdote:<\/em> I recall an instance early in my career when a team member skipped the grounding step, resulting in a dangerous potential difference. It was a stark reminder that safety protocols should never be overlooked.<\/li>\n\n\n\n<li><strong>Gather the Right Tools:<\/strong><br>Typical resistance measurement equipment includes:\n<ul class=\"wp-block-list\">\n<li>A digital micro-ohmmeter or resistance bridge.<\/li>\n\n\n\n<li>High-current test leads and Kelvin clamps.<\/li>\n\n\n\n<li>Safety gear, including insulated gloves and eye protection.<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>Inspect Connections and Terminals:<\/strong><br>Check that all test lead connectors are clean and free of corrosion. A clean connection reduces measurement errors.<\/li>\n<\/ol>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Making the Connections<\/strong><\/h2>\n\n\n\n<p>The process of connecting test leads can vary slightly depending on the type of transformer and the test equipment used. However, the general steps are as follows:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Select the Measurement Points:<\/strong><br>Identify the winding terminals you\u2019ll be testing (e.g., HV winding, LV winding, tap positions). For transformers with multiple windings, it\u2019s often best to start with the high-voltage side and move to the low-voltage side.<\/li>\n\n\n\n<li><strong>Establish a Four-Wire Connection:<\/strong><br>Using a four-wire (Kelvin) configuration helps eliminate errors due to lead resistance. This setup involves:\n<ul class=\"wp-block-list\">\n<li>Two leads supplying the test current.<\/li>\n\n\n\n<li>Two separate leads measuring the voltage drop.<br>The result is a highly accurate resistance reading, as the voltage measurement is independent of the current-carrying lead\u2019s resistance.<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>Secure the Connections:<\/strong><br>Attach the clamps or probes firmly to the terminals. Make sure that there\u2019s no movement that could introduce noise or fluctuating readings.<br><em>Personal Anecdote:<\/em> Once, during a field test in a substation, a loose clamp led to erratic readings, causing unnecessary delays. From that point, I made it a habit to double-check every connection before starting the measurement.<\/li>\n\n\n\n<li><strong>Confirm Polarity and Test Settings:<\/strong><br>Before applying current, verify that the polarity of the connections matches the equipment\u2019s requirements. Set the instrument to the appropriate range for the expected resistance values. Most transformer winding resistances will be low, often in the milliohm range.<\/li>\n<\/ol>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Conducting the Measurement<\/strong><\/h2>\n\n\n\n<p>Once the connections are secure, proceed as follows:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Apply the Test Current:<\/strong><br>Turn on the test equipment and allow it to stabilize. Some instruments automatically select the appropriate current based on the resistance range, while others may require manual adjustment.<\/li>\n\n\n\n<li><strong>Take Multiple Readings:<\/strong><br>For consistency, take multiple readings at each test point and average the results. This helps account for minor fluctuations and ensures more reliable data.<\/li>\n\n\n\n<li><strong>Record the Data:<\/strong><br>Document the resistance values, ambient temperature, and any other relevant conditions. This information will be vital for comparing against baseline measurements in future tests.<\/li>\n<\/ol>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Common Challenges and Troubleshooting<\/strong><\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>High Resistance Readings:<\/strong>\n<ul class=\"wp-block-list\">\n<li>Possible causes include poor connections, dirty terminals, or damaged test leads.<\/li>\n\n\n\n<li>Solution: Clean the terminals, reseat the clamps, and verify the lead condition.<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>Inconsistent Results:<\/strong>\n<ul class=\"wp-block-list\">\n<li>Could be due to loose connections, fluctuating test current, or electromagnetic interference.<\/li>\n\n\n\n<li>Solution: Check all connections, ensure a stable power supply, and move any interfering devices away from the test area.<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>Temperature Variations:<\/strong>\n<ul class=\"wp-block-list\">\n<li>Resistance values can change with temperature.<\/li>\n\n\n\n<li>Solution: Record ambient temperature and, if possible, use temperature compensation or correction factors provided by the transformer manufacturer.<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Final Checks and Wrap-Up<\/strong><\/h2>\n\n\n\n<p>After completing the measurements:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Disconnect Test Equipment Safely:<\/strong><br>Turn off the test instrument before removing the leads. Ensure the transformer remains grounded until all connections are removed.<\/li>\n\n\n\n<li><strong>Review the Results:<\/strong><br>Compare the measured values against previous tests or manufacturer specifications. Look for trends that might indicate developing issues.<\/li>\n\n\n\n<li><strong>Document the Process:<\/strong><br>Keeping a detailed record of the steps taken and the findings ensures that future tests are easier to replicate and interpret.<\/li>\n<\/ol>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Conclusion<\/strong><\/h2>\n\n\n\n<p>Accurate resistance measurement connections are the cornerstone of reliable transformer diagnostics. By following these practical guidelines\u2014ensuring proper preparation, using the correct equipment, and carefully establishing connections\u2014electric power industry workers can maintain high standards of safety and performance.<\/p>\n\n\n\n<p><em>Personal Anecdote:<\/em> In my years of fieldwork, the most successful test teams were always the ones who followed a systematic approach, double-checked every connection, and took pride in their attention to detail. By adopting these best practices, you can ensure that each resistance measurement is not only accurate but also contributes to the transformer\u2019s long-term reliability.<\/p>","protected":false},"excerpt":{"rendered":"<p>Introduction Resistance measurements are a fundamental part of transformer maintenance and diagnostics. Ensuring that the connections for these tests are made correctly not only guarantees accurate readings but also maintains safety and efficiency. In this article, we\u2019ll dive into practical steps, key considerations, and real-world advice on how to set up resistance measurement connections for [&hellip;]<\/p>","protected":false},"author":1,"featured_media":2841,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"om_disable_all_campaigns":false,"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"categories":[11],"tags":[],"class_list":["post-3787","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-transformer-testing"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.0 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Resistance Measurement Connections for Transformers: A Detailed Guide - HVTestTech \u2013 High Voltage Testing Equipment Experts<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/hvtesttech.com\/da\/resistance-measurement-connections-for-transformers-a-detailed-guide\/\" \/>\n<meta property=\"og:locale\" content=\"da_DK\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Resistance Measurement Connections for Transformers: A Detailed Guide - HVTestTech \u2013 High Voltage Testing Equipment Experts\" \/>\n<meta property=\"og:description\" content=\"Introduction Resistance measurements are a fundamental part of transformer maintenance and diagnostics. Ensuring that the connections for these tests are made correctly not only guarantees accurate readings but also maintains safety and efficiency. In this article, we\u2019ll dive into practical steps, key considerations, and real-world advice on how to set up resistance measurement connections for [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/hvtesttech.com\/da\/resistance-measurement-connections-for-transformers-a-detailed-guide\/\" \/>\n<meta property=\"og:site_name\" content=\"HVTestTech \u2013 High Voltage Testing Equipment Experts\" \/>\n<meta property=\"article:published_time\" content=\"2025-01-16T12:53:32+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-12-02T01:30:33+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/hvtesttech.com\/wp-content\/uploads\/2024\/09\/46.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"600\" \/>\n\t<meta property=\"og:image:height\" content=\"338\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"John Roberts\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Skrevet af\" \/>\n\t<meta name=\"twitter:data1\" content=\"John Roberts\" \/>\n\t<meta name=\"twitter:label2\" content=\"Estimeret l\u00e6setid\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutter\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/hvtesttech.com\/resistance-measurement-connections-for-transformers-a-detailed-guide\/\",\"url\":\"https:\/\/hvtesttech.com\/resistance-measurement-connections-for-transformers-a-detailed-guide\/\",\"name\":\"Resistance Measurement Connections for Transformers: A Detailed Guide - HVTestTech \u2013 High Voltage Testing Equipment Experts\",\"isPartOf\":{\"@id\":\"https:\/\/hvtesttech.com\/es\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/hvtesttech.com\/resistance-measurement-connections-for-transformers-a-detailed-guide\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/hvtesttech.com\/resistance-measurement-connections-for-transformers-a-detailed-guide\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/hvtesttech.com\/wp-content\/uploads\/2024\/09\/46.jpg\",\"datePublished\":\"2025-01-16T12:53:32+00:00\",\"dateModified\":\"2025-12-02T01:30:33+00:00\",\"author\":{\"@id\":\"https:\/\/hvtesttech.com\/es\/#\/schema\/person\/422ac5e84e61a55051982d614d95e28c\"},\"breadcrumb\":{\"@id\":\"https:\/\/hvtesttech.com\/resistance-measurement-connections-for-transformers-a-detailed-guide\/#breadcrumb\"},\"inLanguage\":\"da-DK\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/hvtesttech.com\/resistance-measurement-connections-for-transformers-a-detailed-guide\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"da-DK\",\"@id\":\"https:\/\/hvtesttech.com\/resistance-measurement-connections-for-transformers-a-detailed-guide\/#primaryimage\",\"url\":\"https:\/\/hvtesttech.com\/wp-content\/uploads\/2024\/09\/46.jpg\",\"contentUrl\":\"https:\/\/hvtesttech.com\/wp-content\/uploads\/2024\/09\/46.jpg\",\"width\":600,\"height\":338},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/hvtesttech.com\/resistance-measurement-connections-for-transformers-a-detailed-guide\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/hvtesttech.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Resistance Measurement Connections for Transformers: A Detailed Guide\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/hvtesttech.com\/es\/#website\",\"url\":\"https:\/\/hvtesttech.com\/es\/\",\"name\":\"HVTestTech \u2013 High Voltage Testing Equipment Experts\",\"description\":\"Precision Testing Solutions for Electrical Safety and Performance\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/hvtesttech.com\/es\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"da-DK\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/hvtesttech.com\/es\/#\/schema\/person\/422ac5e84e61a55051982d614d95e28c\",\"name\":\"John Roberts\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"da-DK\",\"@id\":\"https:\/\/hvtesttech.com\/es\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/51561face8e05db040d8c4bf07795c74aad101c223419f5c83069fd695a2d790?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/51561face8e05db040d8c4bf07795c74aad101c223419f5c83069fd695a2d790?s=96&d=mm&r=g\",\"caption\":\"John Roberts\"},\"description\":\"I am John Roberts, a professional electrical testing expert with over 35 years of experience in power systems. I specialize in using advanced testing equipment to maintain and improve electrical infrastructure. As a leader and mentor, I guide my team through complex power projects, always prioritizing safety and efficiency. My innovative approach and commitment to team development have earned me respect in the engineering community, establishing me as a trusted authority in electrical testing and power system reliability.\",\"sameAs\":[\"https:\/\/hvtesttech.com\"],\"url\":\"https:\/\/hvtesttech.com\/da\/author\/salehvtesttech-com\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Resistance Measurement Connections for Transformers: A Detailed Guide - HVTestTech \u2013 High Voltage Testing Equipment Experts","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/hvtesttech.com\/da\/resistance-measurement-connections-for-transformers-a-detailed-guide\/","og_locale":"da_DK","og_type":"article","og_title":"Resistance Measurement Connections for Transformers: A Detailed Guide - HVTestTech \u2013 High Voltage Testing Equipment Experts","og_description":"Introduction Resistance measurements are a fundamental part of transformer maintenance and diagnostics. Ensuring that the connections for these tests are made correctly not only guarantees accurate readings but also maintains safety and efficiency. In this article, we\u2019ll dive into practical steps, key considerations, and real-world advice on how to set up resistance measurement connections for [&hellip;]","og_url":"https:\/\/hvtesttech.com\/da\/resistance-measurement-connections-for-transformers-a-detailed-guide\/","og_site_name":"HVTestTech \u2013 High Voltage Testing Equipment Experts","article_published_time":"2025-01-16T12:53:32+00:00","article_modified_time":"2025-12-02T01:30:33+00:00","og_image":[{"width":600,"height":338,"url":"https:\/\/hvtesttech.com\/wp-content\/uploads\/2024\/09\/46.jpg","type":"image\/jpeg"}],"author":"John Roberts","twitter_card":"summary_large_image","twitter_misc":{"Skrevet af":"John Roberts","Estimeret l\u00e6setid":"5 minutter"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/hvtesttech.com\/resistance-measurement-connections-for-transformers-a-detailed-guide\/","url":"https:\/\/hvtesttech.com\/resistance-measurement-connections-for-transformers-a-detailed-guide\/","name":"Resistance Measurement Connections for Transformers: A Detailed Guide - HVTestTech \u2013 High Voltage Testing Equipment Experts","isPartOf":{"@id":"https:\/\/hvtesttech.com\/es\/#website"},"primaryImageOfPage":{"@id":"https:\/\/hvtesttech.com\/resistance-measurement-connections-for-transformers-a-detailed-guide\/#primaryimage"},"image":{"@id":"https:\/\/hvtesttech.com\/resistance-measurement-connections-for-transformers-a-detailed-guide\/#primaryimage"},"thumbnailUrl":"https:\/\/hvtesttech.com\/wp-content\/uploads\/2024\/09\/46.jpg","datePublished":"2025-01-16T12:53:32+00:00","dateModified":"2025-12-02T01:30:33+00:00","author":{"@id":"https:\/\/hvtesttech.com\/es\/#\/schema\/person\/422ac5e84e61a55051982d614d95e28c"},"breadcrumb":{"@id":"https:\/\/hvtesttech.com\/resistance-measurement-connections-for-transformers-a-detailed-guide\/#breadcrumb"},"inLanguage":"da-DK","potentialAction":[{"@type":"ReadAction","target":["https:\/\/hvtesttech.com\/resistance-measurement-connections-for-transformers-a-detailed-guide\/"]}]},{"@type":"ImageObject","inLanguage":"da-DK","@id":"https:\/\/hvtesttech.com\/resistance-measurement-connections-for-transformers-a-detailed-guide\/#primaryimage","url":"https:\/\/hvtesttech.com\/wp-content\/uploads\/2024\/09\/46.jpg","contentUrl":"https:\/\/hvtesttech.com\/wp-content\/uploads\/2024\/09\/46.jpg","width":600,"height":338},{"@type":"BreadcrumbList","@id":"https:\/\/hvtesttech.com\/resistance-measurement-connections-for-transformers-a-detailed-guide\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/hvtesttech.com\/"},{"@type":"ListItem","position":2,"name":"Resistance Measurement Connections for Transformers: A Detailed Guide"}]},{"@type":"WebSite","@id":"https:\/\/hvtesttech.com\/es\/#website","url":"https:\/\/hvtesttech.com\/es\/","name":"HVTestTech \u2013 High Voltage Testing Equipment Experts","description":"Precision Testing Solutions for Electrical Safety and Performance","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/hvtesttech.com\/es\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"da-DK"},{"@type":"Person","@id":"https:\/\/hvtesttech.com\/es\/#\/schema\/person\/422ac5e84e61a55051982d614d95e28c","name":"John Roberts","image":{"@type":"ImageObject","inLanguage":"da-DK","@id":"https:\/\/hvtesttech.com\/es\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/51561face8e05db040d8c4bf07795c74aad101c223419f5c83069fd695a2d790?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/51561face8e05db040d8c4bf07795c74aad101c223419f5c83069fd695a2d790?s=96&d=mm&r=g","caption":"John Roberts"},"description":"I am John Roberts, a professional electrical testing expert with over 35 years of experience in power systems. I specialize in using advanced testing equipment to maintain and improve electrical infrastructure. As a leader and mentor, I guide my team through complex power projects, always prioritizing safety and efficiency. My innovative approach and commitment to team development have earned me respect in the engineering community, establishing me as a trusted authority in electrical testing and power system reliability.","sameAs":["https:\/\/hvtesttech.com"],"url":"https:\/\/hvtesttech.com\/da\/author\/salehvtesttech-com\/"}]}},"_links":{"self":[{"href":"https:\/\/hvtesttech.com\/da\/wp-json\/wp\/v2\/posts\/3787","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/hvtesttech.com\/da\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/hvtesttech.com\/da\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/hvtesttech.com\/da\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/hvtesttech.com\/da\/wp-json\/wp\/v2\/comments?post=3787"}],"version-history":[{"count":1,"href":"https:\/\/hvtesttech.com\/da\/wp-json\/wp\/v2\/posts\/3787\/revisions"}],"predecessor-version":[{"id":3788,"href":"https:\/\/hvtesttech.com\/da\/wp-json\/wp\/v2\/posts\/3787\/revisions\/3788"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/hvtesttech.com\/da\/wp-json\/wp\/v2\/media\/2841"}],"wp:attachment":[{"href":"https:\/\/hvtesttech.com\/da\/wp-json\/wp\/v2\/media?parent=3787"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/hvtesttech.com\/da\/wp-json\/wp\/v2\/categories?post=3787"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/hvtesttech.com\/da\/wp-json\/wp\/v2\/tags?post=3787"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}