{"id":4921,"date":"2025-12-29T09:17:13","date_gmt":"2025-12-29T09:17:13","guid":{"rendered":"https:\/\/hvtesttech.com\/?p=4921"},"modified":"2025-12-29T09:17:14","modified_gmt":"2025-12-29T09:17:14","slug":"did-i-account-for-the-tap-changer-the-first-question-in-every-ratio-mystery","status":"publish","type":"post","link":"https:\/\/hvtesttech.com\/ru\/did-i-account-for-the-tap-changer-the-first-question-in-every-ratio-mystery\/","title":{"rendered":"Did I Account for the Tap Changer? The First Question in Every Ratio Mystery"},"content":{"rendered":"<p>You\u2019ve run the test. The screen flashes a ratio deviation of <strong>2.3%<\/strong>\u2014far beyond the acceptable \u00b10.5%. Your mind races: <em>Is this a shorted turn? A serious winding fault?<\/em> Before you call for a costly internal inspection, stop. In over two decades of transformer diagnostics, I\u2019ve learned that the first and most critical question is the simplest: <strong>\u201cIs the tap changer where I think it is?\u201d<\/strong><\/p>\n\n\n\n<p>More transformer \u201cfaults\u201d are diagnosed in the control cabinet than in the lab. A mismatch between the physical tap position and the tested position is the single most common source of confusing, alarming TTR results.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">The Disconnect Between the Dial and the Core<\/h2>\n\n\n\n<p>Modern transformers, especially those with <strong>On-Load Tap Changers (OLTC)<\/strong>, are marvels of engineering. A motorized drive mechanism, controlled from a remote panel, seamlessly adjusts taps under load to regulate voltage. Herein lies the pitfall.<\/p>\n\n\n\n<p>Consider this real scenario from a utility substation. My team was called to investigate a 50 MVA transformer that failed a routine ratio test. The SCADA system and local position indicator both showed <strong>Tap 5N<\/strong> (neutral). Our high-precision HV HTRC tester, however, consistently reported a ratio matching the theoretical value for <strong>Tap 3L<\/strong> (lower). The initial fear was a major wiring or internal fault.<\/p>\n\n\n\n<p>The resolution wasn\u2019t in the windings; it was in the linkage. We manually cranked the tap changer through its full range and back to neutral. A faint \u201cclunk\u201d was heard at the marked neutral position, but the mechanism had a slight drag. A subsequent test showed a perfect ratio at the true neutral. The issue? A slightly stiff mechanical linkage causing the tap changer to rest one position off from what the indicator reported. No fault, just a maintenance flag.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Your Diagnostic Checklist: Ruling Out the Tap Changer Illusion<\/h2>\n\n\n\n<p>When a ratio is \u201cwrong,\u201d a systematic, on-site verification is your most powerful tool. Here is the exact process I follow, honed by years of field surprises:<\/p>\n\n\n\n<p><strong>1. The Physical Verification (Get Your Hands Dirty):<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Locate the Position Indicator:<\/strong> On the tap changer itself, not just the remote panel. There is usually a mechanical drum or dial with numbers.<\/li>\n\n\n\n<li><strong>Sight and Confirm:<\/strong> Physically sight and confirm the number. For older transformers, wipe off grime. The painted numbers can fade or become misaligned.<\/li>\n\n\n\n<li><strong>The \u201cBump\u201d Test (for De-energized OLTCs):<\/strong> With the transformer de-energized and proper safety protocols, use the manual hand crank. Gently try to move it off and back onto the position. Feel for positive engagement. A loose mechanism can settle between positions.<\/li>\n<\/ul>\n\n\n\n<p><strong>2. The Electrical Verification (Let the Data Speak):<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Test Multiple Taps:<\/strong> Don\u2019t just test the nominal tap. A professional TTR tester should allow you to program and test multiple tap positions rapidly. Test the suspected position, plus one above and one below.<\/li>\n\n\n\n<li><strong>Analyze the Pattern:<\/strong> Compare your measured ratios to the transformer\u2019s <strong>nameplate schedule<\/strong>. If your \u201cTap 5\u201d reading matches the nameplate value for Tap 4, you have a consistent one-position offset, pointing squarely to an indicator\/alignment issue. A random, nonsensical mismatch might indicate a deeper problem.<\/li>\n\n\n\n<li><strong>Check Winding Resistance:<\/strong> If doubt remains, a DC winding resistance test on the same tap can be a brilliant cross-check. An unexpected resistance value can confirm a misaligned tap or even point to a bad contact within the tap changer diverter switch.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">How the Right Tester Turns Panic into Procedure<\/h2>\n\n\n\n<p>A precise, feature-rich TTR tester doesn\u2019t just measure a ratio\u2014it guides you through this diagnostic maze. The <strong>HV HTRC Series<\/strong> is built for this exact reality. When I face a puzzling ratio, here\u2019s how it streamlines the investigation:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Effortless Multi-Tap Sequencing:<\/strong> I simply input the transformer\u2019s nameplate ratio schedule for various taps. The tester then automates the entire verification, measuring and comparing results across several positions in minutes, creating an instant, clear picture of alignment or misalignment.<\/li>\n\n\n\n<li><strong>Unambiguous, High-Resolution Results:<\/strong> With <strong>0.05% basic accuracy<\/strong>, the difference between Tap 4 and Tap 5 isn\u2019t a fuzzy maybe; it\u2019s a definitive numerical fact. This precision removes instrument error from the list of suspects, forcing the focus onto the transformer itself.<\/li>\n\n\n\n<li><strong>Integrated Workflow:<\/strong> By storing results for winding resistance and excitation current alongside TTR, the HTRC allows me to see all the evidence on one screen. A ratio anomaly with a perfectly normal winding resistance on that tap is the classic signature of an indicator problem, not a winding fault.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">The Professional\u2019s First Rule<\/h2>\n\n\n\n<p>The tap changer is the transformer\u2019s moving part. Where there is motion and indication, there is room for discrepancy. My first rule of transformer diagnostics is this: <strong>Never trust an abnormal ratio until you have physically and electrically verified the tap changer position.<\/strong><\/p>\n\n\n\n<p>This isn\u2019t just about avoiding embarrassment; it\u2019s about efficiency and cost. Spending an hour on meticulous verification can prevent days of unnecessary downtime and thousands in invasive investigation costs. In our field, the best troubleshooting often starts with the assumption of a simple, mechanical cause before pursuing complex, electrical faults.<\/p>\n\n\n\n<p><strong>Don\u2019t let a misleading indicator dictate your maintenance decisions.<\/strong><br>Equip yourself with the precision and diagnostic workflow to know the difference. <strong><a href=\"https:\/\/hvtesttech.com\/ru\/transformer-turns-ratio-ttr-testers\/\">Explore the HV HTRC Series TTR Tester and see how it helps you verify first, diagnose second.<\/a><\/strong><\/p>\n\n\n\n<p><\/p>","protected":false},"excerpt":{"rendered":"<p>You\u2019ve run the test. The screen flashes a ratio deviation of 2.3%\u2014far beyond the acceptable \u00b10.5%. Your mind races: Is this a shorted turn? A serious winding fault? Before you call for a costly internal inspection, stop. In over two decades of transformer diagnostics, I\u2019ve learned that the first and most critical question is the [&hellip;]<\/p>","protected":false},"author":1,"featured_media":2841,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"om_disable_all_campaigns":false,"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"categories":[11],"tags":[],"class_list":["post-4921","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-transformer-testing"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.0 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Did I Account for the Tap Changer? The First Question in Every Ratio Mystery - HVTestTech \u2013 High Voltage Testing Equipment Experts<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/hvtesttech.com\/ru\/did-i-account-for-the-tap-changer-the-first-question-in-every-ratio-mystery\/\" \/>\n<meta property=\"og:locale\" content=\"ru_RU\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Did I Account for the Tap Changer? The First Question in Every Ratio Mystery - HVTestTech \u2013 High Voltage Testing Equipment Experts\" \/>\n<meta property=\"og:description\" content=\"You\u2019ve run the test. The screen flashes a ratio deviation of 2.3%\u2014far beyond the acceptable \u00b10.5%. Your mind races: Is this a shorted turn? A serious winding fault? Before you call for a costly internal inspection, stop. In over two decades of transformer diagnostics, I\u2019ve learned that the first and most critical question is the [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/hvtesttech.com\/ru\/did-i-account-for-the-tap-changer-the-first-question-in-every-ratio-mystery\/\" \/>\n<meta property=\"og:site_name\" content=\"HVTestTech \u2013 High Voltage Testing Equipment Experts\" \/>\n<meta property=\"article:published_time\" content=\"2025-12-29T09:17:13+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-12-29T09:17:14+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/hvtesttech.com\/wp-content\/uploads\/2024\/09\/46.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"600\" \/>\n\t<meta property=\"og:image:height\" content=\"338\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"John Roberts\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u041d\u0430\u043f\u0438\u0441\u0430\u043d\u043e \u0430\u0432\u0442\u043e\u0440\u043e\u043c\" \/>\n\t<meta name=\"twitter:data1\" content=\"John Roberts\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u041f\u0440\u0438\u043c\u0435\u0440\u043d\u043e\u0435 \u0432\u0440\u0435\u043c\u044f \u0434\u043b\u044f \u0447\u0442\u0435\u043d\u0438\u044f\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 \u043c\u0438\u043d\u0443\u0442\u044b\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/hvtesttech.com\/did-i-account-for-the-tap-changer-the-first-question-in-every-ratio-mystery\/\",\"url\":\"https:\/\/hvtesttech.com\/did-i-account-for-the-tap-changer-the-first-question-in-every-ratio-mystery\/\",\"name\":\"Did I Account for the Tap Changer? The First Question in Every Ratio Mystery - HVTestTech \u2013 High Voltage Testing Equipment Experts\",\"isPartOf\":{\"@id\":\"https:\/\/hvtesttech.com\/es\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/hvtesttech.com\/did-i-account-for-the-tap-changer-the-first-question-in-every-ratio-mystery\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/hvtesttech.com\/did-i-account-for-the-tap-changer-the-first-question-in-every-ratio-mystery\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/hvtesttech.com\/wp-content\/uploads\/2024\/09\/46.jpg\",\"datePublished\":\"2025-12-29T09:17:13+00:00\",\"dateModified\":\"2025-12-29T09:17:14+00:00\",\"author\":{\"@id\":\"https:\/\/hvtesttech.com\/es\/#\/schema\/person\/422ac5e84e61a55051982d614d95e28c\"},\"breadcrumb\":{\"@id\":\"https:\/\/hvtesttech.com\/did-i-account-for-the-tap-changer-the-first-question-in-every-ratio-mystery\/#breadcrumb\"},\"inLanguage\":\"ru-RU\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/hvtesttech.com\/did-i-account-for-the-tap-changer-the-first-question-in-every-ratio-mystery\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ru-RU\",\"@id\":\"https:\/\/hvtesttech.com\/did-i-account-for-the-tap-changer-the-first-question-in-every-ratio-mystery\/#primaryimage\",\"url\":\"https:\/\/hvtesttech.com\/wp-content\/uploads\/2024\/09\/46.jpg\",\"contentUrl\":\"https:\/\/hvtesttech.com\/wp-content\/uploads\/2024\/09\/46.jpg\",\"width\":600,\"height\":338},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/hvtesttech.com\/did-i-account-for-the-tap-changer-the-first-question-in-every-ratio-mystery\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/hvtesttech.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Did I Account for the Tap Changer? The First Question in Every Ratio Mystery\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/hvtesttech.com\/es\/#website\",\"url\":\"https:\/\/hvtesttech.com\/es\/\",\"name\":\"HVTestTech \u2013 High Voltage Testing Equipment Experts\",\"description\":\"Precision Testing Solutions for Electrical Safety and Performance\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/hvtesttech.com\/es\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ru-RU\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/hvtesttech.com\/es\/#\/schema\/person\/422ac5e84e61a55051982d614d95e28c\",\"name\":\"John Roberts\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ru-RU\",\"@id\":\"https:\/\/hvtesttech.com\/es\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/51561face8e05db040d8c4bf07795c74aad101c223419f5c83069fd695a2d790?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/51561face8e05db040d8c4bf07795c74aad101c223419f5c83069fd695a2d790?s=96&d=mm&r=g\",\"caption\":\"John Roberts\"},\"description\":\"I am John Roberts, a professional electrical testing expert with over 35 years of experience in power systems. I specialize in using advanced testing equipment to maintain and improve electrical infrastructure. As a leader and mentor, I guide my team through complex power projects, always prioritizing safety and efficiency. My innovative approach and commitment to team development have earned me respect in the engineering community, establishing me as a trusted authority in electrical testing and power system reliability.\",\"sameAs\":[\"https:\/\/hvtesttech.com\"],\"url\":\"https:\/\/hvtesttech.com\/ru\/author\/salehvtesttech-com\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Did I Account for the Tap Changer? The First Question in Every Ratio Mystery - HVTestTech \u2013 High Voltage Testing Equipment Experts","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/hvtesttech.com\/ru\/did-i-account-for-the-tap-changer-the-first-question-in-every-ratio-mystery\/","og_locale":"ru_RU","og_type":"article","og_title":"Did I Account for the Tap Changer? The First Question in Every Ratio Mystery - HVTestTech \u2013 High Voltage Testing Equipment Experts","og_description":"You\u2019ve run the test. The screen flashes a ratio deviation of 2.3%\u2014far beyond the acceptable \u00b10.5%. Your mind races: Is this a shorted turn? A serious winding fault? Before you call for a costly internal inspection, stop. In over two decades of transformer diagnostics, I\u2019ve learned that the first and most critical question is the [&hellip;]","og_url":"https:\/\/hvtesttech.com\/ru\/did-i-account-for-the-tap-changer-the-first-question-in-every-ratio-mystery\/","og_site_name":"HVTestTech \u2013 High Voltage Testing Equipment Experts","article_published_time":"2025-12-29T09:17:13+00:00","article_modified_time":"2025-12-29T09:17:14+00:00","og_image":[{"width":600,"height":338,"url":"https:\/\/hvtesttech.com\/wp-content\/uploads\/2024\/09\/46.jpg","type":"image\/jpeg"}],"author":"John Roberts","twitter_card":"summary_large_image","twitter_misc":{"\u041d\u0430\u043f\u0438\u0441\u0430\u043d\u043e \u0430\u0432\u0442\u043e\u0440\u043e\u043c":"John Roberts","\u041f\u0440\u0438\u043c\u0435\u0440\u043d\u043e\u0435 \u0432\u0440\u0435\u043c\u044f \u0434\u043b\u044f \u0447\u0442\u0435\u043d\u0438\u044f":"4 \u043c\u0438\u043d\u0443\u0442\u044b"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/hvtesttech.com\/did-i-account-for-the-tap-changer-the-first-question-in-every-ratio-mystery\/","url":"https:\/\/hvtesttech.com\/did-i-account-for-the-tap-changer-the-first-question-in-every-ratio-mystery\/","name":"Did I Account for the Tap Changer? The First Question in Every Ratio Mystery - HVTestTech \u2013 High Voltage Testing Equipment Experts","isPartOf":{"@id":"https:\/\/hvtesttech.com\/es\/#website"},"primaryImageOfPage":{"@id":"https:\/\/hvtesttech.com\/did-i-account-for-the-tap-changer-the-first-question-in-every-ratio-mystery\/#primaryimage"},"image":{"@id":"https:\/\/hvtesttech.com\/did-i-account-for-the-tap-changer-the-first-question-in-every-ratio-mystery\/#primaryimage"},"thumbnailUrl":"https:\/\/hvtesttech.com\/wp-content\/uploads\/2024\/09\/46.jpg","datePublished":"2025-12-29T09:17:13+00:00","dateModified":"2025-12-29T09:17:14+00:00","author":{"@id":"https:\/\/hvtesttech.com\/es\/#\/schema\/person\/422ac5e84e61a55051982d614d95e28c"},"breadcrumb":{"@id":"https:\/\/hvtesttech.com\/did-i-account-for-the-tap-changer-the-first-question-in-every-ratio-mystery\/#breadcrumb"},"inLanguage":"ru-RU","potentialAction":[{"@type":"ReadAction","target":["https:\/\/hvtesttech.com\/did-i-account-for-the-tap-changer-the-first-question-in-every-ratio-mystery\/"]}]},{"@type":"ImageObject","inLanguage":"ru-RU","@id":"https:\/\/hvtesttech.com\/did-i-account-for-the-tap-changer-the-first-question-in-every-ratio-mystery\/#primaryimage","url":"https:\/\/hvtesttech.com\/wp-content\/uploads\/2024\/09\/46.jpg","contentUrl":"https:\/\/hvtesttech.com\/wp-content\/uploads\/2024\/09\/46.jpg","width":600,"height":338},{"@type":"BreadcrumbList","@id":"https:\/\/hvtesttech.com\/did-i-account-for-the-tap-changer-the-first-question-in-every-ratio-mystery\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/hvtesttech.com\/"},{"@type":"ListItem","position":2,"name":"Did I Account for the Tap Changer? The First Question in Every Ratio Mystery"}]},{"@type":"WebSite","@id":"https:\/\/hvtesttech.com\/es\/#website","url":"https:\/\/hvtesttech.com\/es\/","name":"HVTestTech \u2013 High Voltage Testing Equipment Experts","description":"Precision Testing Solutions for Electrical Safety and Performance","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/hvtesttech.com\/es\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ru-RU"},{"@type":"Person","@id":"https:\/\/hvtesttech.com\/es\/#\/schema\/person\/422ac5e84e61a55051982d614d95e28c","name":"John Roberts","image":{"@type":"ImageObject","inLanguage":"ru-RU","@id":"https:\/\/hvtesttech.com\/es\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/51561face8e05db040d8c4bf07795c74aad101c223419f5c83069fd695a2d790?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/51561face8e05db040d8c4bf07795c74aad101c223419f5c83069fd695a2d790?s=96&d=mm&r=g","caption":"John Roberts"},"description":"I am John Roberts, a professional electrical testing expert with over 35 years of experience in power systems. I specialize in using advanced testing equipment to maintain and improve electrical infrastructure. As a leader and mentor, I guide my team through complex power projects, always prioritizing safety and efficiency. My innovative approach and commitment to team development have earned me respect in the engineering community, establishing me as a trusted authority in electrical testing and power system reliability.","sameAs":["https:\/\/hvtesttech.com"],"url":"https:\/\/hvtesttech.com\/ru\/author\/salehvtesttech-com\/"}]}},"_links":{"self":[{"href":"https:\/\/hvtesttech.com\/ru\/wp-json\/wp\/v2\/posts\/4921","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/hvtesttech.com\/ru\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/hvtesttech.com\/ru\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/hvtesttech.com\/ru\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/hvtesttech.com\/ru\/wp-json\/wp\/v2\/comments?post=4921"}],"version-history":[{"count":1,"href":"https:\/\/hvtesttech.com\/ru\/wp-json\/wp\/v2\/posts\/4921\/revisions"}],"predecessor-version":[{"id":4922,"href":"https:\/\/hvtesttech.com\/ru\/wp-json\/wp\/v2\/posts\/4921\/revisions\/4922"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/hvtesttech.com\/ru\/wp-json\/wp\/v2\/media\/2841"}],"wp:attachment":[{"href":"https:\/\/hvtesttech.com\/ru\/wp-json\/wp\/v2\/media?parent=4921"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/hvtesttech.com\/ru\/wp-json\/wp\/v2\/categories?post=4921"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/hvtesttech.com\/ru\/wp-json\/wp\/v2\/tags?post=4921"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}