Cable Identifier for Energized and De-Energized Cables

Our Cable Identifier is a versatile tool designed for accurately identifying both energized and de-energized cables in complex electrical environments. Whether you’re dealing with high-voltage power lines or low-voltage control cables, this device ensures safe and precise cable identification, minimizing the risk of accidental disconnections or damage.

lizhvtesttech@gmail.com

+1 323 522 4623

Key Features:

  • Dual-Mode Operation: Capable of identifying cables in both energized and de-energized states, making it suitable for a wide range of applications.
  • High Sensitivity: Ensures accurate detection and identification even in dense cable bundles, reducing the risk of errors.
  • Safety Assurance: Designed with safety in mind, the device operates without requiring direct contact with high-voltage cables, protecting the operator.
  • Easy to Use: Features an intuitive interface and clear display, allowing for quick and efficient identification by both experienced technicians and novices.
  • Portable Design: Compact and lightweight, making it easy to carry and use in various field environments.

Applications:

  • Utility Companies: Ideal for identifying cables during maintenance or repairs in power distribution networks, ensuring the correct cables are isolated or connected.
  • Industrial Facilities: Perfect for safely identifying control and power cables in manufacturing plants, preventing costly downtime due to misidentification.
  • Construction Sites: Essential for safely identifying cables in both energized and de-energized states during construction and renovation projects.

Technical Specifications:

1. Baseline and Working Conditions

FactorBaseline ConditionsWorking ConditionsRemarks
Ambient Temperature23°C ± 1°C-10°C to 40°C/
Environmental Humidity40% to 60%<80%/
Measured Voltage and Current Frequency50Hz ± 1Hz45Hz to 70HzWhen testing voltage and current
Receiver Operating Voltage7.4V ± 0.5V7.4V ± 1V/
Transmitter Working Voltage11.1V ± 0.5V11.1V ± 1.5V/
External Electric Field, Magnetic FieldShould be avoided//
Tested Cable PositionThe cable under test is at the approximate geometric center of the flexible current clamp//

2. Transmitter Specifications

SpecificationDetails
FunctionTransmit composite pulse frequency current signal, display remaining battery voltage, dynamic indication of transmission status
Power Supply11.1V large-capacity rechargeable lithium battery, fully charged, continuous work for about 8 hours
Output MethodCaliper coupling during live identification; direct connection output during power failure identification
Transmit Frequency625Hz, 1562Hz, 2500Hz, 10KHz (when live identification), adjustable using arrow keys
Pulse Voltage500V (during power failure recognition)
Pulse Current5A max (depending on the size of the loop resistance)
Pulse Frequency1 time/second
Pulse Width2ms
Display ModeLarge LCD real-time display of remaining battery voltage, with backlight
Operating Temperature-10°C to 40°C
Storage Conditions-20°C to 50°C, ≤ 95% RH, no condensation
Backlight ControlYes, white backlight
Instrument QualityTransmitter: 2.5kg; Transmitting Clamp: 1.08kg; Total Mass: 4.4kg (including receiver)
Battery PowerLow battery voltage icon displays at 9.65V; automatic shutdown at 9.5V
Charger12.6V DC charger
Charging PortRound charging interface, DC logo
Anti-StressTransmitter housed in a special toolbox design, withstands approx. 200kg pressure
Withstand VoltageAC 3700V/rms (top and bottom of the instrument box)
Electromagnetic PropertiesIEC61326 (EMC)
Reference Safety RegulationsIEC61010-1 (CAT III 300V, CAT IV 150V, pollution degree 2)

3. Receiver Specifications

SpecificationDetails
FunctionLive cable identification, power outage cable identification; AC voltage, current, frequency measurement
Power Supply7.4V large-capacity rechargeable lithium battery, USB charging interface, continuous operation for about 6 hours
Rated CurrentApprox. 300mA max
Display Mode3.5-inch true color LCD screen display, color icon indication
Signal CalibrationYes, calibrate the transmit signal. Conditions for successful recognition: current percentage of received and transmitted signals between 75% and 135% of the calibration value
Direction RecognitionTransmitting clamp, receiving clamp, and loading signal must align in the same direction for successful identification
Target Cable IdentificationGreen tick icon (√)
Non-Target Cable IdentificationRed-orange cross icon (×)
Coil Inner Diameter200mm (customizable for larger calibers)
Examination RangePower Failure Identification: Detects pulse signals with loop resistance 0Ω to 10kΩ; requires transmitter battery power above 11V for high resistance detection.
Live Identification: Detects pulse signals with loop resistance 0Ω to 200Ω; requires transmitter battery power above 11V for high resistance detection.
Measurement RangeAC Voltage: 0.00V to 600V (50Hz/60Hz)
AC Current: 0.00A to 5000A (50Hz/60Hz)
Current Frequency: 45Hz to 70Hz
PrecisionAC Voltage: ±2% ±3dgt
AC Current: ±2% ±3dgt
Current Frequency: ±2% ±3dgt
Identification SignalColor signal amplitude and digital display
Detection RateApprox. 1 detection/second
Gain AdjustmentAdjust signal magnification using left and right arrow keys; optimal signal amplitude is between 10 and 100
Backlight ControlAdjust LCD backlight brightness using up and down arrow keys in function selection interface
Automatic ShutdownDevice automatically shuts down after approx. 30 minutes of inactivity to conserve battery power
Battery VoltageLow battery voltage icon displays when voltage falls below 6.5V, prompting a recharge
Charger9V DC charger
Charging PortUSB charging port
Working Temperature and Humidity-10°C to 40°C; below 80% RH
Storage Temperature and Humidity-10°C to 50°C, ≤ 95% RH, no condensation
Withstand VoltageAC 2000V/rms (front and rear ends of the shell)
Safety RegulationsIEC61010-1 CAT III 600V, IEC61010-031, IEC61326, pollution degree 2

Why Choose Our Cable Identifier?

  • Versatile Performance: Suitable for both energized and de-energized cables, providing flexibility in various testing scenarios.
  • Precision and Reliability: High sensitivity and accuracy ensure that you always identify the correct cable, avoiding potential hazards.
  • User-Friendly Design: The straightforward interface and lightweight build make it an essential tool for any electrical professional.

Contact Us:

Ensure the safety and efficiency of your operations with our reliable Cable Identifier. Contact us today for more information or to request a quote.

email: Sale@hvtesttech.com or call us: +1 323 522 4623

amAmharic